P4108A / P4116 HARDWIRED ZONE EXPANSION MODULES

Premier systems can be expanded in increments of 8 and 16 hardwired zones up to the rated capacity of each system using multiple P4108A and P4116 hardwired zone expansion modules.

Each module can be added as required anywhere on the system Combus providing the utmost in flexibility for hardwired zone expansion to meet customer requirements now and in the future!

Partner Premier SeriesP4108A - 8 Zone Expansion Module

  • provides 8 programmable hardwired zones

  • zone supervision : zones can be NC with no EOLR, NO/NC with single EOLR or NC with double EOLR (5600ohm resistors)

  • 30 programmable zone types & 8 zone options

  • VAUX output : 12VDC, 250mA max. from Combus

  • optional built-in tamper switch supervised by system

  • connection for external tamper… supervised by system

  • connect up to 1,000' (305m) from control panel via COMBUS

  • operating environment
    - 32 to 122°F (0 to 50°C)
    - 90% RH non-condensing

  • current draw

    ...30mA (from Combus) plus power required for VAUX output if used

Partner Premier SeriesP4108A - Typical System Arrangement

Typical System Arrangement

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.

P4108A / P4116 HARDWIRED ZONE EXPANSION MODULES

Partner Premier SeriesP4116 - 16 Zone Expansion Module

  • provides 8 programmable hardwired zones

  • zone supervision : zones can be NC with no EOLR, NO/NC with single EOLR or NC with double EOLR (5600ohm resistors)

  • 30 programmable zone types & 8 zone options

  • VAUX output : 12VDC, 250mA max. from Combus

  • connection for external tamper… supervised by system

  • connect up to 1,000' (305m) from control panel via COMBUS

  • operating environment
    - 32 to 122°F (0 to 50°C)
    - 90% RH non-condensing


  • current draw


    ...30mA (from Combus) plus power required for VAUX output if used

Partner Premier SeriesP4116 Ordering Information

    P4108A

...8 hardwired zone expansion module

    P4108AT

...8 hardwired zone expansion module with built-in tamper switch (for use with PC5001CP enclosure only)

    P4116

...16 hardwired zone expansion module

Partner Premier SeriesP4116A - Listings

    USA

    UL864...

    Control Units System (L, CS, -A, M, SS, WF)
    UL1610...

    Central Station Burglar Alarm
    UL609...

    Local Burglar Alarm
    UL365...

    Police Station Burglar Alarm
    UL985...

    Household Fire Warning
    UL1023...

    Household Burglar Alarm

    CANADA

    ULC-S527...

    Central Station Fire Alarm
    ULC-S302...

    Central & Monitoring Station Burglar Alarm
    ULC-S303...

    Local Alarm (Commercial Burglary)
    ULC-S310...

    Household Burglar Alarm
    ULC-S545...

    Household Fire Warning
    UL294...

    Access Control