| |
|
Partner Premier
meets today’s challenges with the seamless integration of Security,
Access Control, Fire Alarm and Automation features that single
function systems cannot match.
Hardwired
input/output expansion over a four-wire COMBUS, wireless input
expansion, and two-wire addressable input expansion all combine
for installation simplicity, flexibility, and economy.
Tomorrow’s
challenges are solved today because Access Control, Fire Alarm,
Escort Audio Assist, and Automation features are designed into
the Premier security panel, ready to be implemented when you need
them.
|
| |
| Up
to 20 Keypads |
|
- up to
16 hardwired and 4 wireless keypads… choose from:
|
| - |
PRS400 series plain language keypads |
|
| - |
PRS400F
series plain language keypads with red bezels |
|
| - |
PWLS910
wireless handheld keypad |
|
| |
| Expand
Up to 128 Zones |
|
| Hardwired
Expansion |
|
- up to
128 zones using…
|
| - |
P4108A eight zone expansion modules |
|
| - |
P4116
sixteen zone expansion modules |
|
| |
| Addressable
Expansion |
|
- up to
112 addressable zones using…DSC
addressable devices on up to 2 addressable loops
|
| |
| Wireless
Expansion |
|
- up to
64 wireless zones using… P4164RS wireless receiver and DSC wireless
detectors
|
| |
| 8
Partitions… 1,000 User Codes |
|
| 3,000
Event Buffer |
| |
| Local
& Remote Upload/Download |
| |
| Advanced
Communications |
|
- supports
SIA, Contact ID, and 20bps formats
- LINKS1000™
cellular communication
- LINKS2150™
and LINKS2450™ long range radio communication
- DVACS
communication using P4400 module
- event
initiated personal paging
- 3 phone
numbers
- 9 account
numbers
|
|
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
|
| |
| Efficient
Installation |
| |
- addressable
loop expansion
|
| - |
2-wire addressable loops expand system to full zone capacity
without the added cost of system expansion modules |
|
|
- COMBUS
hardwired expansion
|
| - |
simple hardwired system expansion using standard, non-shielded,
4 conductor station wire to connect hardwired keypads
and modules up to 1,000ft (305m) from the main control
panel |
|
| |
| Output
Expansion |
|
- up to 144
low current outputs using… up to nine P4216 sixteen output modules
- up to
64 relay outputs using… up to sixteen P4204 or P4204CF power
supply/4-relay output modules
|
| |
| Annunciation |
|
- point/graphic
annunciation using…
|
| - |
P4632
thirty two zone annunciator |
| - |
P4664 sixty four zone annunciator |
|
|
- fire zone
annunciation using…P4612 fire zone annunciator
|
|
- system
printer using… P4400 printer/DVACS module
|
| |
| Integrated
Access Control |
|
- up to
32 doors using… sixteen P4820 two reader access control modules
- up to
1,000 access cards
- multiple
reader technologies… Polaris mag-stripe, ShadowProx proximity,
HID proximity, 26 bit standard Wiegand
|
| |
| Integrated
Voice Assisted Security & Building Automation |
|
- P4580 Escort…
operates in conjunction with any touch-tone telephone to provide
voice assisted security and automation control for up to 32
X-10 devices
|
| |
| ULC
Central Station Fire Alarm |
|
- all the
features of the standard security versions plus special fire
system modules…
|
| - |
P4701 fire module with supervised smoke zone, waterflow
zone, dual supervised communicator outputs |
|
| - |
P4612
twelve zone fire annunciator |
|
| - |
P4350R
fire system external battery charger |
| - |
P4204CF
power supply/4-relay output panel |
| - |
PRS400F
series plain language keypads with red bezels |
|
|
|
|
|
| S E C U R I
T Y |
|
|
 |
 |
|
|
|
|
|
P-864
-
8 zone main panel
-
expandable to 64 zones
-
1 addressable loop for up to 56 addressable devices
-
16 LCD keypads/system
-
4 partitions
-
1,000 user codes
-
3,000 event buffer
-
5 account numbers
3 phone numbers
|
|
P-16-128
-
16 zone main panel
-
expandable to 128 zones
-
2 addressable loops for up to 112 addressable devices
-
16 LCD keypads/system
-
8 partitions
-
1,000 user codes
-
3,000 event buffer
-
9 account numbers
3 phone numbers
|
| |
|
|
 |
| |
|
|
- 1
supervised bell zone
-
PCLINK™ for local upload/download
-
remote upload/download with Comm-Link DLS software
|
|
-
supervised digital alarm communicator
-
opt. attack - resistant cabinet
-
space for two 7Ah lead-acid rechargeable batteries
|
|
|
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
|
|
|
 |
 |
|
|
|
|
- two line,
32 character display
- adjustable
display brightness & contrast
- LCD display
and keys backlit for low light viewing
- 'backlighting
boost' for extra lighting when any key is pressed
- display
zone and system status, trouble conditions, event buffer, and
system instructions
- piezo
buzzer provides audible feedback for correct/incorrect key entries,
entry/exit alert, and system trouble conditions
- 'global'
or partition operation
- dedicated
function keys for… panic, auxiliary, & fire
- keypad
activated duress code
- 5 programmable
function keys
- Trouble,
Armed, and Ready LEDs
- tamper
versions available
|
|
|
|
A C C E S S
C O N T R O L |
|
   |
|
|

- 16 modules/system
- 32 readers
total
- 1,000
access cards
- full off-line
operation
- arm/disarm
partitions & postpone auto-arm
by access card or access card and code
from outside the protected space
- 2 low current
outputs per door
- 4 inputs
per door… door contact, request-to-exit
input, arm, and postpone auto-arm
- 64 access
levels
- 99 seven-day
schedules
- 4 holiday
groups, 730 holidays
- individual
door-unlock schedules
|
|
Multiple
Reader Technologies
Polaris… Mag-Stripe Readers/Cards

ShadowProx… Proximity Readers/Cards
HID… Proximity Readers/Cards
|
|
|
|
|
| F I R E A L A
R M |
|
|
 |
 |
|
|
|
|
| All
the security features of the P-864/P-16-128 plus additional fire
features… |
|
- red cabinet
- P4701
fire module includes…
|
| … |
one
2-wire ClassB/StyleB supervised smoke zone |
|
|
… |
dual
supervised digital alarm communicator outputs |
|
| … |
one
ClassB/StyleB waterflow zone |
|
| … |
common
fire alarm & fire trouble relays, form 'C', 2A, 30VDC
contacts |
|
- all panel
& expansion zones are configurable for waterflow, or fire supervisory
- ULC Listed
for Central Station Fire Alarm
|
|
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
|
|
|
|
A U T O M A T
I O N |
|
   |
|
|
The
P4580 Escort operates in conjunction with any touch-tone telephone
to provide an easy to understand plain language interface for
the Maxsys security system. Escort allows the telephone to be
used as a keypad while providing the user with operational and
programming voice prompts as well as plain language system status
reports. In addition, Escort acts as an interface to X-10 automation
control devices and provides voice assisted operation and programming
of these devices.
System
Status & Control - Voice Prompt Assisted…
- system
status from any local or remote touch tone telephone
- system
control using any local or remote touch tone telephone
- Global
or Partition access
- extensive
library of voice prompts for security and building automation
system control and status feedback
- 180 word
standard library & 241 word user programmable library
- up to
6 words per voice prompt.
|
|

Automation
Control…
- built-in
power line interface for up to 32 X-10 control devices
- programmable
event activation using 16 event timers and 8 schedules
- control
outputs via local or remote touch tone telephone keypad
|
|
|
|
|
| A
D R E S S A B L E
E X P A N S I O N |
|
|
| Use
2-wire addressable loops to easily expand to full system capacity
without the added cost of system expansion modules. |
|
| P-864........ |
|
add
up to 56 addressable devices on one addressable loop |
|
| P-16-128... |
|
add
up to 112 addressable devices on two addressable loops |
|
|
|
| |
|
|
 |
 |
|
 |
-
exceptional microphone frequency range provides excellent
sound capture at low sound levels and distances up to
25ft (7.6m)
-
detects breakage of all common types of glass including
plate, wired, tempered and laminated
-
built-in tamper switch
-
AFT-100 glassbreak tester available
|
|
|
|
|
 |
 |
|
 |
Partner
AMS-220… 2-wire photoelectric smoke detector
Partner
AMS-220T… includes 135°F (57°C) fixed temp. heat sensor
|
|
-
red solid-state LED indicator light
- magnet-activated
sensitivity test switch
-
continuous self-test for low sensitivity
-
manual and programmable scheduled tests for low sensitivity
and alarm operation
-
locking/non-locking mounting plate
|
|
|
|
|
 |
 |
|
 |
-
multi-level PIR signal processing
-
dual element low noise sensor
-
high level static & transient protection
-
high white light & RF immunity
-
temperature compensation
-
tamper switch
-
4 lenses available
-
up to 50'L x 60'W (15.2 x 18.3m) coverage
|
|
|
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
|
|
|
 |
 |
|
 |
-
ceiling mount
-
quad element low noise PIR
-
high white light & RF immunity
-
multi-level signal processing
-
temperature compensation
-
up to 40'Ø (12.2m) coverage
|
|
|
|
|
 |
 |
|
 |
-
multi-level PIR signal processing
-
two dual-element low noise sensors
-
high static and transient protection
-
high white light & RF immunity
-
temperature compensation
-
tamper switch
-
40'L x 50'W (12.2 x 15.2m) coverage
|
|
|
|
|
 |
 |
|
|

|
Partner
AMP-700… magnetic door/window contact with built-in tamper
switch
|
| |
|
|
Partner
AMP-701… 3 inputs to monitor external NC alarm, tamper,
and trouble contacts
Partner
AMP-702… NO supervised input contact. EOL supervised for
fire applications
|
|
|
|
|
W I R E L E S
S E X P A N S
I O N |
|
   |
|
|

|
|
- capacity
… wireless zones
– P-864… 56 zones
– P-16-128… 64 zones
… 16 PWLS909 wireless keys
… 4 PWLS910 wireless keypads
(in addition to hardwired keypads)
- all detectors
are fully supervised for communication integrity
- 900MHz
true Spread Spectrum technology
- easy sensor
enroll process
|
|
|
|
|
|
W I R E L E S S
C O N T R O L S &
D E T E C T O R S |
|
|
|
 |
 |
|
 |
- press
2 buttons for 2 seconds to initiate a panic alarm
-
water resistant
-
pendant test function
-
supervised for low battery
-
each pendant is a wireless zone
-
sealed non-replaceable battery
|
|
|
|
|
 |
 |
|
 |
-
4 programmable function buttons of users choice such
as… STAY arm, AWAY arm, Disarm, Fire, Auxiliary, Panic,
Command Outputs
-
supervised for low battery
-
3 A76 batteries (supplied)
|
|
|
|
|
|
 |
 |
|
 |
-
performs most hardwired keypad functions including entry
of access code to arm/disarm system and other functions
-
keys 1-4 are programmable func. keys
-
separate F, A, P, keys
-
supervised for low battery
-
3 AAA batteries (supplied)
|
|
| |
|
|
 |
 |
|
 |
-
4 interchangeable lenses : wall to wall, corridor, curtain,
and pet alley
-
coverage up to:
50'L x 60'W (15.2 x 18.3m)
-
high traffic shut-down
-
fully supervised
-
4 AAA batteries (supplied)
|
|
| |
|
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
|
|
|
 |
 |
|
 |
-
may be used as a magnetic door or window contact or
terminal connection for an external contact
-
2 reed switch contacts for ease of placement
-
fully supervised
-
3 AAA batteries (supplied)
|
|
|
|
|
 |
 |
|
 |
-
exceptional microphone frequency range provides excellent
sound capture at low sound levels and distances up to
25ft (7.6m)
-
detects breakage of all common types of framed glass
including plate, wired, tempered, and laminated
-
fully supervised
-
3 AA batteries (supplied)
|
|
|
|
|
|
|
|
| HARDWIRED
EXPANSION |
|
| INPUT |
|
 |
 |
|
-
P4108A… 8 zone input module
-
P4108AT… 8 zone input module with tamper (use with P5001CP
cabinet)
-
P4116… 16 zone input module
-
30 programmable zone types…
- all zones programmable as NC,
EOL, DEOL
-
250mA, 12VDC auxiliary power for local devices
-
add up to 56 zones on P-864/CF
-
add up to 112 zones on P-16-128/CF
OUTPUT
|
|
|
|
|
 |
 |
|
-
16 programmable outputs
-
outputs rated for 50mA @ 12VDC
-
59 programmable output options
-
up to 9 modules/system for 144 total outputs on all
systems
|
|
|
|
|
 |
 |
|
-
up to 1.0A @ 12VDC power for…
- COMBUS power
- local input devices
- local output signals
-
4 form 'C' programmable relays
- contacts rated for 2A @ 30VDC
-
59 programmable output options
-
supervised for…
- AC power fail
- aux. supply fault
- low/disconnected battery
-
P-864… up to 12 modules per system for 48 relays total
-
P-16-128… up to 16 modules per system for 64 relays
total
|
|
| |
|
|
 |
 |
|
|
Packaged
version of P4204 for UL listed commercial fire systems…
-
up to 550mA @ 12VDC power for…
- COMBUS power
- local input devices
- local output signals
-
PT1016 transfmr. incl…16VAC, 40VA
-
P4052CR cabinet, red
-
space for one additional P4108A module
-
space for two 7AH gel-cell batteries
…all other specs the same as the P4204
|
|
|
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . . . . . . . .
|
|
| ANNUNCIATORS |
|
 |
 |
|

Remote
system annunciators for point or graphic display of
zone, partition, and system status information…
-
display up to 144 points per system with multiple annunciators
-
connect anywhere on the COMBUS
-
egg-crate backplane for flexible indicator location
-
red, yellow and green LED assemblies
-
pre-printed point display transparency
-
clear transparencies (2) for custom graphics
P4632…
32 point - 8.5" x 11" (21.6 x 27.9cm) display area
P4664…
64 point - 11" x 17" (27.9 x 43.2cm) display area
|
|
|
|
|
 |
 |
|
 |
-
point annunciation of…
|
| - |
10
fire zones |
|
| - |
2
supervisory zones |
|
| - |
common
zone trouble |
|
| - |
common
bell trouble |
|
| - |
system
trouble |
|
| - |
‘AC
ON’ LED |
|
|
|
|